OVERALL DESCRIPTION Console Operation The console is designed with everything that is necessary for you to program and operate your Omni IIe control

Página 3 - Contents

6- UP ARROW The Up Arrow key is used to scroll through menus and lists. The Up Arrow is used to scroll back through a list (for example, if you have

Página 4

When using the arrow keys to scroll through lists of areas, buttons, codes, temperature zones, units, or zones, only the named items are displayed. I

Página 5

Confirmation Beep When you have successfully completed a function, such as entering a program or changing a setup item, the console will beep once.

Página 6

SECURITY SYSTEM OPERATION Disarming the Security System and Silencing Alarms Before going any further, you should know how to disarm your security

Página 7

2 = NIGHT The NIGHT mode is used when you are asleep and everyone in your household is at home. In the Night mode, your doors, windows, and non-slee

Página 8

Quick Arm For extra convenience, the Omni IIe can be armed by simply pressing the DAY, NIGHT, or AWAY button twice, eliminating the need to enter the

Página 9 - INTRODUCTION

#=GOTO To Bypass or Restore a zone in another area, you must first "go to" that area by selecting #=GOTO. AREA: ENTER AREA: At th

Página 10 - OVERALL DESCRIPTION

For more information on the digital and voice dialer - See Digital Dialer and Voice Dialer. • The system continues to sound all alarms and flash the

Página 11 - Display Menus

Police Emergency When the 1 key and the 3 keys are pressed simultaneously, the Police Emergency alarm is activated. This alarm operates exactly the

Página 12

Copyright © 2001-2006 Home Automation, Inc. All Rights Reserved

Página 13 - Omni IIe Maintenance

Trouble Indications The Omni IIe constantly monitors the alarm zones and several internal matters and will alert you if it detects trouble. The part

Página 14 - SECURITY SYSTEM OPERATION

Manager Code The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access functions th

Página 15 - Using Shortcut Keys

If the ' 0 ' (ALL) key had been selected, the display will show: DISARM ALL AREAS ENTER CODE: #=AREA As the four-digit code

Página 16 - Bypassing Zones

Testing Your System HAI recommends testing your system on a weekly basis to ensure that you are fully protected. 1. Notify your Central Station tha

Página 17

CONTROL Control Commands The control features of the Omni IIe make it easy and convenient to control almost any light or appliance from the console

Página 18 - Emergency Keys

When set to UPB, the Omni IIe controller can: ¾ Send commands (on, off, bright, dim and level) to individual switches and modules ¾ Receive command

Página 19 - Alarm Cancel

indicator is turned off. Likewise, if the “On” indicator or one of the scene indicators is illuminated, and then all of the lighting loads are turned

Página 20 - Trouble Indications

When set to RadioRA, the Omni IIe controller can: ¾ Send commands (on, off, and level) to individual Switches and Dimmers ¾ Receive status (on and

Página 21

Unit Numbers Omni IIe systems have 128 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 module unit numbers

Página 22 - GOTO Area

Configuring Lighting Scenes in an HLC Room Lighting scenes are created by configuring light levels for HLC lighting devices in a room. Each HLC dev

Página 23 - Testing Your System

Contents INTRODUCTION...

Página 24 - CONTROL

Entry Lights 0=OFF 1=ON 2=DIM 3=BRT ↓ Entry Lights 4=LVL 5=RMP 9=TIM #=STA↑ ¾ Press 0 (OFF) to turn the selected unit off. ¾ Press 1 (ON) to turn

Página 25

¾ Press 0 (OFF) to turn the selected unit off. ¾ Press 1 (ON) to turn the selected unit on. ¾ Press 2 (DIM) to dim the selected unit (1-9 steps, e

Página 26 - About Lutron RadioRA

Scene Command (Compose) If Compose lighting switches are part of your installation, the Scene (SCN) command is used to set a group of lights to prede

Página 27 - House Codes

When a counter is decremented to zero, the "When Unit Off" macro is executed. A counter will not decrement below zero. The counter will, h

Página 28 - Controlling Units

ALL 0=OFF 1=ON 2=SCN 3=LINK↓ ALL 4=PHANTOM 5=CENLIT ↑ All Lights On At the ALL prompt, press the 1 (LIGHTS ON) key. The consol

Página 29

Scene Commands Scene Commands are used to Set Scenes, issue a Scene On command, and issue a Scene Off command. To issue Scene Commands, press the 2

Página 30

Activating and Deactivating Links A special UPB command called “Link On” (activate) is used to command all of the devices that have the same Link to

Página 31

Enter the CentraLite Scene number (1-255) followed be the ' # ' key. CENLIT SCENE 1 0=OFF 1=ON When a CentraLite Scene is turned on, all o

Página 32 - Internal Flags

HAI RC-Series Thermostats The following control actions are allowed for HAI Communicating Thermostats: • Set heating setpoints • Set cooling setp

Página 33 - All On / Off

Upstairs FAN 0=AUTO 1=ON Thermostats may be switched between hold mode and the normal run mode. While in hold mode, the thermostat does not

Página 34

CONTROL ...

Página 35

The following control actions are allowed on PESMs: • Turn Energy Saver On and Off • Turn Energy Saver On and Off for a specified time • Set heati

Página 36

0=OFF 1=ON 2=HEAT ↓ Downstairs 3=COOL 9=TIME #=STAT ↑ ENTER TIME MINUTES (1-99) #=H/M/S Downstairs FOR

Página 37 - Temperature Control

For negative temperatures (-1o to -40o), press the ' # ' key prior to entering the temperature to make the number negative. A Celsius temp

Página 38 - HAI RC-Series Thermostats

Status The Status function is used to display the status of various items in the system. To enter the status menu, from the top-level display or the

Página 39

Press 1 (CTRL) to view the current status of each unit and to configure the HLC device that is assigned for each unit. The console will display:

Página 40

The Zone Status menu allows you to view and scroll through the status of each zone input. To enter the Zone menu, from the Status menu, press the 2 (

Página 41

The next series of displays shows the current analog reading for each security zone input. The displays show the readings for zones 1-48. 1=1

Página 42 - Humidity

To view your event log, from the top-level display or from the main menu, press the 7 key, then enter your code. The arrow keys may be used to scroll

Página 43 - 1 = CTRL (CONTROL UNITS)

You may enter the message number followed by the ' # ' key to display that message, or simply press the down arrow key to scroll through a l

Página 44 - 2 = ZONE

The built-in serial ports (J1-J3) on the controller are assigned to Serial Port 1 - Serial Port 3, respectively. Serial port 4 is a Serial Interface

Página 45

Status...

Página 46 - Event Log

TELEPHONE CONTROL Telephone Interface Your Omni IIe is equipped with a built-in telephone response feature that allows you to control and access the

Página 47 - Messages

Phone Access Denied - Remote Lockout The Omni IIe has a remote lockout feature to discourage youngsters (and adults who act that way) from trying to

Página 48

1 - Control Press 1 from the MAIN MENU to get to the CONTROL menu. If voice descriptions have been programmed, after a three-second delay, the syste

Página 49

Press the temperature zone you wish to control, then press #. Press the ' 0 ' key to select all HAI Thermostats. This is a simple way to b

Página 50 - TELEPHONE CONTROL

8 - Phone This command allows you to record and verify the address. If an optional HAI Two-Way Audio Module is being used, this command also allows

Página 51 - Main Menu

Emergency Dial-Out Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer." Digital Dial

Página 52

What the Omni IIe Voice Dialer Does When an alarm is activated, the Omni IIe will wait the Dial Out Delay. If your system is monitored by a central

Página 53 - 7 - Events

PC Access Omni IIe is capable of communicating with an IBM compatible personal computer (PC). The PC can be local (in-house) or remote. The PC must

Página 54 - 9 - Good-Bye

192.168.0.101192.168.0.50192.168.0.51HAI Omni IIeControllerHub orRouterComputerComputer To connect to an Omni IIe controller on a local network us

Página 55 - Voice Dialer

To connect to an Omni IIe controller on a local network using HAI PC Access, under Configure >> Network enter the controller’s IP

Página 56

SETUP...

Página 57 - PC Access

SETUP Configuration and Advanced Control Programming (ACP) The Setup menu is used to configure operating parameters, program your system to do its a

Página 58 - Local Network

You can specify the access (on/off) times for the code; this is, the time periods during which the code is valid. CODE 2 ON TIME: 8:00 AM

Página 59 - Local / Wide Area Network

Advanced Control Programming (ACP) Your Omni IIe can be programmed to do automated control and security functions on a time schedule or in response t

Página 60 - Set Up Codes

Menu 1 - Programs for a particular control unit number Menu 2 - All Security related programs Menu 3 - Programs for a particular macro button Menu

Página 61 - Set Up Time

The arrow keys are used to scroll through the programs. Pressing the ' # ' key while a particular program is displayed will allow that prog

Página 62

Edit Programs When Selecting the 1 (WHEN) key, from the Edit Program menu, allows the time or button/event that activates the program to be changed.

Página 63

Button and Event Programs Selecting 2 (BUTTON), from the "Edit When" menu, sets up a program to be activated when a macro button is execute

Página 64 - Edit Programs

Corresponding Switch Table Switch Omni IIe UPB 6-Button Keypad UPB 8-Button Keypad RadioRA Master Control ALC 4-Button 1 2 On Button 1 or E

Página 65 - Edit Programs When

- Selecting 3 (AREA) allows you to specify that the event button is activated only when the specified area is armed or disarmed. You will be prompt

Página 66 - Button and Event Programs

UPB Link Event Buttons When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link Goto

Página 68

Finally, you are prompted to specify the command that activates the event button: WHEN X-10 A1: 0=OFF 1=ON 2=SCENE After specifying the X-1

Página 69 - ANY TYPE ↓

Pro-Link also has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Link searches through al

Página 70

If the selected unit is not capable of dim and bright commands, only a single menu is shown. Porch Light (Unit Name) 0=OFF 1=ON 9=TIM #=STA

Página 71 - Edit Program Command

Select (0-6) to arm the system into the desired mode or select the 8 key to Bypass and the 9 key to Restore a security zone. If area arming is being

Página 72

Program Message Commands Select the 8 (MESSAGE) key to show, log, clear, say, phone, or send a message. Specify the desired command - See Message.

Página 73

The unit is displayed and the display prompts for the state of the unit: IF Porch Light: 0=OFF 1=ON Program Security Mode Conditions Press t

Página 74 - Edit Program Condition

Choose "NONE" when editing a program and choose not to conditionalize the program. SELECT CONDITION: NEVER  Cho

Página 75

Set Up Dial The Set Up Dial menu is used to configure all of the telephone related items for the Omni IIe. To enter the Set Up Dial menu, from the S

Página 76 - SELECT CONDITION:

Dial Out Number 1 Dial Out Number 1 is one of the 8 numbers that are stored in the system. In the event of an alarm, these numbers are dialed in the

Página 77 - Set Up Dial

Set Up Arming To configure different arming and disarming options, from the Setup menu, press the 5 (ARM) key. Entry Delay The Entry Delay is the t

Página 79 - Set Up Arming

Enable Quick Arm The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter your

Página 80 - Set up Miscellaneous

Enable Freeze Alarm If there are one or more Thermostat or PESM in a system, they can also be used to detect a freeze condition - See Freeze Alarm.

Página 81

House Codes 1-4 All On This feature allows you to choose if House Code 1-4 will respond to the “All On” command. Press the 0 key to select No and th

Página 82

Latitude, Longitude, and Time Zone The system automatically calculates the time of sunrise and sunset each day. Sunrise/sunset can be specified as t

Página 83

DST START WEEKEND: FIRST SUNDAY #=CHNG  DST END MONTH: 10 1-12 0=DISABLE  DST END WEEKEND:

Página 84 - ↓), scroll to the

Encryption Key Encryption and decryption of data between the Omni IIe controller and the connected device is based on the Advanced Encryption Stand

Página 85 - Set Up Names

Set Up Voice The Omni IIe can be set up to speak descriptive names such as "FRONT DOOR" for control zones, units, buttons, codes, temperatu

Página 86 - Set Up Address

UNDERWRITER'S LABORATORIES REQUIREMENTS For a complete list of requirements and restrictions when installing the Omni IIe panel in a UL Listed

Página 87 - FIRE ESCAPE PLANNING

FEDERAL COMMUNICATION COMMISSION NOTICE: 1. This equipment complies with Part 68 of FCC Rules. On the door, inside of the Omni IIe enclosure, is a

Página 88

CANADIAN INDUSTRY CANADA NOTICE Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment mee

Página 89

INTRODUCTION Thank you for purchasing your new Omni IIe automation system. You are about to enjoy a new feeling of security, comfort, convenience,

Página 90

APPENDIX A - DIAL OUT PLANNER Use the following dial-out planner to help you set-up the voice dial-out numbers: Omni IIe Voice Dial-Out Planner

Página 91 - INSTRUCTIONS TO CALLED PARTY

INSTRUCTIONS TO CALLED PARTY Dear ___________________________________________________________________ I have programmed my Omni IIe Home Automatio

Página 92

APPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHAR CODE CHAR CODE CHAR CODE CHAR00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18

Página 93

Page 85 APPENDIX C - VOICE DESCRIPTION CODES CODE DESCRIPTION 255 (ADDRESS MSG) 58 (BEEP) 254 (MEMO MESSAGE) 29 (PAUSE) 30 (SHORT PAUSE) 26 A. M

Página 94

Page 86 CODE DESCRIPTION CODE 214 EXTERIOR 215 FACTORY 216 FAILURE 341 FALL 80 FAMILY 81 FAN 342 FATHER’S 343 FAULT 344 FEBRUARY 217 FENCE 5 FIFTEEN

Página 95

Page 87 CODE DESCRIPTION CODE 128 OH 129 ON 130 ONE 444 ONLINE 445 ONLY 233 OPEN 446 OPTION 131 OR 447 OTHER 448 OUT 132 OUTDOOR 133 OUTLET 449 OUTS

Página 96

CODE DESCRIPTION CODE 186 VACATION 249 VALVE 535 VANITY 250 VAULT 536 VCR 537 VIDEO 538 VISITOR 539 VOLUME 540 WAITING DESCRIPTION CODE 541 WALK 542

Página 98

NOTE TO INSTALLER Following installation, this manual shall be left for the homeowner's use. HAI •

Modelos relacionados INC. Omni IIe

Comentários a estes Manuais

Sem comentários