11 RC-1000 Thermostat Installation Instructions DESCRIPTION The RC-1000 is a precision digital thermostat designed for 24 VAC he
1100 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature settings between preset
1111 REMOTE TEMPERATURE SENSOR A remote temperature sensor can be installed to monitor the temperature from a remote location or can be combined with
1122 SETUP AND CONFIGURATION NOTE: For proper operation of the features of this thermostat, the Time and Date must be set. Even when connected t
1133 System Type *Conventional Dual Fuel Heat Pump1 Heat Pump *Auto Changeover No Fan With Heat Auto Changeover Fan On With Heat Auto Changeover Fan
1144 Cool Minimum On The number of minutes the thermostat forces the cooling system to remain on before turning off. Raising this number will increas
1155 Auxiliary Heat Differential: This determines how far from the setpoint the temperature has to be before the auxiliary heat turns on. This is on
1166 TROUBLESHOOTING TIPS SYMPTOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMPTOM ACTION TO
22 Location When replacing an existing thermostat, install the RC-1000 in the same location. If the existing location doesn't meet the followin
33 Connect each wire to the terminal strip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 7. Form th
44 TYPICAL WIRING DIAGRAMS CAUTION: Do not short gas valve, fan, heat relay, or cool relay...even momentarily. Do not attempt to h
55 3. When configured as a conventional thermostat, by default this thermostat does not turn the fan on with a call for heat. If the furnace require
66 Single Stage Conventional 24VAC "HOT"Heat24VAC Common*FanCoolUP24VACCONTROLTRANSMFOMERFan RelayCool RelayHeat RelayHVAC SYSTEMTHERMOSTAT
77 About Heat Pump Systems 1) Terminal 5 (O) is energized for cooling Terminal 6 (B) is energized for heating In most applications, the reversing
88 Heat Pump (2 Stage Heat / 1 Stage Cool) 24VAC Common24VAC "HOT"Auxilirary HeatCompressorGround FaultFanCompressor RelayAux Heat RelayFan
99 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been preprogrammed with energy saving program schedules in accordance with the ENERGY STAR® prog
Comentários a estes Manuais